β Saved Configurations (0 )
No products selected yet.
Configure a product and click "Save Configuration"
✉ Email Selected Products
☰ Copy All Configurations
▢ Generate QR Code
✕ οΈ Clear All
By Parameter
Select by measurement parameter: pH, chlorine, turbidity, and more
β
By Industry
Find solutions tailored for your industry application
β
Part Number Converter
Convert between legacy and current part numbers
β
Literature
Data sheets, application notes, and technical documentation
β
Requests
Project requests, technical support, CCRP, and service requests
→
β Back
☰ CWA Solutions RFQ Form
Fill out the form below to submit a project request for ABB CWA Solutions. The project name will generate automatically.
β Back
▪ Literature Library
Browse and search data sheets, application notes, and technical documentation
Filter by Category:
All Categories
Accessories
Chlorine
Color
Colorimetric Analyzers
Conductivity
Dissolved Organics
Dissolved Oxygen
Fluoride / Ammonia ISE
Hydrazine
Nitrate / Nitrite
Phosphate
Silica
Sodium
Transmitters
Turbidity / TSS
UV Absorbance
pH / ORP Sensors
Search:
Showing all 83 documents
⌕
No documents found matching your search.
β Back
pH / ORP
How acidic or basic the water is, and how strong the disinfectant or oxidizer is
Chlorine
Disinfection monitoring
Turbidity / TSS
Water clarity
Conductivity
Dissolved salts, minerals, and ions (water purity)
Dissolved Oxygen
Oxygen levels
Ammonia / Ammonium
Water quality control
Phosphate
Phosphorus that feeds algae growth
Aluminum
Drinking water & wastewater
Iron
Water quality monitoring
Manganese
Drinking water control
BOD / COD
Organic matter testing
TOC / DOC
Total & dissolved organic carbon
Silica
Demin plants, boiler drum water & contamination monitoring
Sodium
Demin plants, boiler drum water & contamination monitoring
Spare Parts and Reagents
Search spare parts by product or keyword
Transmitters
New and legacy transmitter options
Sensor Accessories
Click here to access accessories for pH/ORP, turbidity, and dissolved oxygen
β Back
Spare Parts and Reagents Lookup
Filter by product family and/or search by part number or description
Filter by Product:
All Products
APA592 / ACA592
ASO550 Sodium Analyzer
AW641 Silica Analyzer
AWT210 Transmitter
Aztec ISE (Ammonia)
Aztec LINE (Colorimetric)
Compression Fittings & O-Rings
General / Accessories
AZA211 InSert
AZA212 InSert
AZA213 InSert
Navigator 600 (Silica/Sodium)
TB(X)5 / TB4 / TB2 Shared
TB(X)5 / TB404 Shared
TB(X)5 pH/ORP Sensors
TB2 Conductivity Sensors
TB4 Conductivity Sensors
TB404 Toroidal Conductivity
Thermocompensators
Search:
Showing all 397 parts
Product
Part Number
Description
⌕
No spare parts found matching your search.
β Back
Transmitters
Select new or legacy transmitter options
New Transmitters
Current transmitter configurations
Legacy Transmitter Converter
Convert TB82, TB84, AWT420, AWT440, and AX4 series transmitters to current models
Module Replacement
Find replacement modules for existing transmitters
β Back
Module Replacement
Which transmitter is this for?
AWT210
AWT210 module replacement
AWT420
AWT420 module replacement
AWT424
AWT424 module replacement
β Back
AWT210 Module Replacement
Pick a communications or sensor option to display the appropriate module.
If a communications module (left side) is needed, select one below:
Communications Module Part Number:
✓ Save Configuration
What type of sensor is this for?
By Sensor Model
By Sensor Type
Select your sensor model:
-- Select Sensor --
APS121
APS131
APS521
APS551
APS731
TB551
TB556
TB557
TB561
TB564
TB587
TB567
TB26
TB254
2085
AC212
AC221
AC213
AC211
TB264
TB27
TB404
TB451
TB454
TB457
TB461
TB465
TB464
TB468
TB47
APS122
APS132
APS522
APS552
APS732
Select sensor type:
-- Select Sensor Type --
Analog pH
Digital pH
2 Electrode Conductivity
4 Electrode Conductivity
Toroidal Conductivity
Sensor Module Part Number:
✓ Save Configuration
β Back
AWT420 Module Replacement
Pick a communications or sensor option to display the appropriate module.
If a communications module (left side) is needed, select one below:
HART
Foundation
Profibus
Modbus
Ethernet
Analog Output
Communications Module Part Number:
✓ Save Configuration
What type of sensor is this for?
By Sensor Model
By Sensor Type
Select your sensor model:
-- Select Sensor --
APS121
APS131
APS521
APS551
APS731
TB551
TB556
TB557
TB561
TB564
TB587
TB567
TB26
TB254
2085
AC212
AC221
AC213
AC211
TB264
TB27
ATS410
TB451
TB454
TB457
TB461
TB465
TB464
TB468
TB47
APS122
APS132
APS522
APS552
APS732
ATS430
ACL420
ADS420
ADS560
ADS565
ACL410
Select sensor type:
-- Select Sensor Type --
Analog pH
Digital Sensor
2 Electrode Conductivity
4 Electrode Conductivity
Sensor Module Part Number:
✓ Save Configuration
β Back
AWT424 Module Replacement
Pick a communications or sensor option to display the appropriate module.
If a communications module (left side) is needed, select one below:
HART
Foundation
Profibus
Modbus
Ethernet
Analog Output
Communications Module Part Number:
💾 Save Configuration
What type of sensor is this for?
By Sensor Model
By Sensor Type
Select your sensor model:
-- Select Sensor --
APS121
APS131
APS521
APS551
APS731
TB551
TB556
TB557
TB561
TB564
TB587
TB567
TB26
TB254
2085
AC212
AC221
AC213
AC211
TB264
TB27
ATS410
TB451
TB454
TB457
TB461
TB465
TB464
TB468
TB47
APS122
APS132
APS522
APS552
APS732
ATS430
ACL420
ADS420
ADS560
ADS565
ACL410
Select sensor type:
-- Select Sensor Type --
Analog pH
Digital Sensor
2 Electrode Conductivity
4 Electrode Conductivity
ℹ️ Note: This module is capable of supporting 2 digital sensors per module.
Sensor Module Part Number:
💾 Save Configuration
β Back
New Transmitter Configuration
Configure a new AWT210 or AWT424 transmitter
Transmitter Configuration
1. How will the transmitter get power?
-- Select --
Through its 4–20 mA signal wires only (loop powered) – 1 sensor (AWT210, 2-wire)
Its own AC or DC power wires – up to 4 sensors (2 inputs, each can take 2 digital sensors) plus relays (AWT424, 4-wire)
2. What enclosure do you need?
-- Select --
Plastic (polycarbonate) – standard, fine for most places
Metal (aluminum) – needed for hazardous-area approvals
3. Sensor Input Module:
-- Select Sensor Module --
No sensor module (base unit only)
Digital EZLink (pH/ORP)
pH/ORP (analog sensors)
Conductivity 2-electrode
Conductivity 4-electrode
Conductivity toroidal
4. How will the reading get to your control system?
HART is standard. It also works as a plain 4–20 mA signal, so choose it even if the site does not use HART.
-- Select --
HART (standard) – also works as a plain 4–20 mA signal
PROFIBUS PA network – only if your plant uses it
FOUNDATION Fieldbus network – only if your plant uses it
5. Will it be in an area with flammable gas or dust (a hazardous area)?
Every AWT210 includes intrinsic safety (IS) approval at no extra cost, so it can move into a hazardous area later. In a non-hazardous area it is wired normally (14–42 V DC, no barrier).
-- Select --
No – general purpose area (IS approval included at no extra cost)
Yes – intrinsically safe (IS) approval, wired through an IS barrier (cFMus, ATEX/IECEx)
Yes – non-incendive and intrinsically safe approval (cFMus, ATEX/IECEx) – metal enclosure only
6. Where will it mount?
The transmitter is rated for outdoor use. The sun shield (weathershield) mainly protects the display from sunlight (UV).
-- Select Mounting Option --
Flat wall – no kit needed
Pipe – pipe-mount kit
Cut-out in a panel door – panel-mount kit
Wall, in direct sun – add a sun (UV) shield
Pipe, in direct sun – pipe-mount kit + sun (UV) shield
2. What enclosure do you need?
-- Select --
Plastic (polycarbonate) – standard, fine for most places
Metal (aluminum) – needed for hazardous-area approvals
3. Power Supply:
-- Select Power Supply --
90 to 265 V AC, 50/60 Hz
21 to 36 V DC
4. Sensor Input Module β Channel 1:
-- Select Sensor Module --
No sensor module (base unit only)
Analog pH/ORP
Conductivity 2-electrode
Conductivity 4-electrode
Digital EZLink
Dual Digital EZLink
Analog Turbidity (4690)
Universal Input Module (UIM)
5. Sensor Input Module β Channel 2:
-- Select Sensor Module --
No sensor module (base unit only)
Analog pH/ORP
Conductivity 2-electrode
Conductivity 4-electrode
Digital EZLink
Dual Digital EZLink
Analog Turbidity (4690)
Universal Input Module (UIM)
6. The transmitter already has two 4–20 mA outputs. Do you need anything added?
-- Select --
No – the two 4–20 mA outputs are enough (most common)
Two more 4–20 mA outputs
HART – only if your plant uses it
Modbus RS-485 network – only if your plant uses it
PROFIBUS DP network – only if your plant uses it
Ethernet network – only if your plant uses it
7. Will it be in an area with flammable gas or dust (a hazardous area)?
-- Select --
No – general purpose area (cULus)
Yes – Class I Div. 2 / Zone 2 (cULus, ATEX/IECEx/UKEx) – metal enclosure only
8. Where will it mount?
The transmitter is rated for outdoor use. The sun shield (weathershield) mainly protects the display from sunlight (UV).
-- Select Mounting Option --
Flat wall – no kit needed
Pipe – pipe-mount kit
Cut-out in a panel door – panel-mount kit
Wall, in direct sun – add a sun (UV) shield
Pipe, in direct sun – pipe-mount kit + sun (UV) shield
Transmitter Configuration
Part Number:
β Back
pH / ORP Measurement Options
Select the type of pH measurement application
Guided pH Selector NEW
Answer a few questions to find the right pH/ORP sensor for your application
Select by Model
Already know what sensor you need? Choose directly from our pH/ORP sensor lineup
InSert Retractable Assembly
Configure an AZA211, AZA212, or AZA213 retractable assembly for 3/4 in. sensors based on your process conditions
β Back
InSert Retractable Assembly Configuration
Answer the questions below. Only the assemblies and materials rated for your process conditions are offered.
β Back
Select by Model
Choose your pH/ORP sensor
General Purpose
Designed for use in: drinking water, municipal wastewater, cooling water, food & beverage
Low Conductivity / Ultrapure Water
Designed for use in: boiler water, demineralized water, power plants, steam water analysis, reverse osmosis, condensate/feedwater
TB5 Sensor
Designed for use in: Pulp & Paper, Oil & Gas, Chemical, Petroleum, Metals, and Mining. The harshest of conditions.
500X Sensor NEW
Designed for use in: Pulp & Paper, Oil & Gas, Chemical, Petroleum, Metals, and Mining. The harshest of conditions.
500 PRO Sensor NEW
3/4 in pH/ORP sensor for industrial process applications. Max 145 PSI. Multiple glass options available.
100E Pg13.5
Economical pH/ORP sensor with Pg13.5 process connection for general purpose applications
β Back to pH/ORP Options
100E Pg13.5 pH/ORP Sensor Configuration
Configure your 100E sensor with Pg13.5 process connection
Sensor Configuration
1. What are you measuring?
-- Select Measurement Type --
pH
ORP
2. Do you want the sensor to measure temperature too?
Most transmitters need temperature to correct the pH reading. Choose Yes unless you are sure.
-- Select --
Yes – include temperature
No – without temperature
3. How does the cable connect to the transmitter?
-- Select Wire Type --
Tinned leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
4. Cable Length:
-- Select Cable Length --
1 m (3.3 ft)
3 m (9.8 ft)
5 m (16.4 ft)
100E Sensor Configuration
Part Number:
β Back
Guided pH Sensor Selection
Answer a few questions to find the right sensor for your application
What segment would this be?
General Purpose Water / Wastewater
Municipal water, drinking water, wastewater treatment plants
ABB_picto_48x48 High Purity Water / Steam Generation
Boiler water, demineralized water, power plant applications
ABB_picto_48x48 Marine Applications
Shipboard systems, seawater, ballast water
ABB_picto_48x48 Industrial Process
Chemical, pulp & paper, oil & gas, mining, metals
What is the process like?
✦ Low-Fouling Process
i.e. Potable Water
⚙ High-Fouling Process
i.e. Wastewater
What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
▪ Analog
Works with any pH transmitter, or when replacing an existing sensor
▣ Digital
ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
Select a size:
PG 13.5
European standard thread
3/4" NPT
National Pipe Thread
✓
Recommended Sensor
100GP General Purpose
Based on your selections, this sensor is ideal for your application.
Configure Sensor β
✓
Recommended Sensor
100E Pg13.5
Economical pH/ORP sensor with Pg13.5 process connection for general purpose applications.
Configure Sensor β
What is the temperature?
℃ <60Β°C / 140Β°F
Lower temperature applications
▲ >60Β°C / 140Β°F
Higher temperature applications
Does the water contain chemicals that can ruin a pH sensor?
Some chemicals attack the inside of a pH sensor and shorten its life. Examples: sulfide (rotten-egg smell), cyanide, ammonia, chlorine, heavy metals such as silver, mercury or copper, and bromide or iodide.
✓ No
None of these are in the water
⚠ Yes or not sure
One or more are present, or you are not sure
✓
Recommended Sensor
500 PRO
The 500 PRO sensor is recommended for your application. Use the configurator to build your part number.
Configure 500 PRO β
What is the conductivity?
▲ >10 ΞΌS/cm Conductivity
Higher conductivity applications
▼ <10 ΞΌS/cm Conductivity
Ultra-low conductivity applications
What is the pressure?
↔ Ambient
Atmospheric pressure conditions
↗ Up to 87 PSI
Pressurized applications
What are the maintenance requirements?
✦ Maintenance-Free Design
Minimal maintenance required
↻ Reservoir Fed
Refillable reservoir system
✓
Recommended: 700 Series Refillable
Extended life, rechargeable reservoir for ultra-pure water applications. Now let's configure your sensor.
Configure Your 700 Series Sensor
1. What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
2. What do you plan to measure?
-- Select --
pH
ORP
3. Select Connection Type:
-- Select --
VarioPin (cable supplied with tagged leads)
4. Select Cable Length:
-- Select --
1 meter (3.3 ft)
3 meters (9.9 ft)
5 meters (16.4 ft)
10 meters (32.8 ft)
3. Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
I already have the cable – sensor only
4. Select Cable Length:
-- Select --
5 . Do you need a flow cell?
-- Select --
None – sensor only
Stainless steel flow cell kit – for boiler or high-purity water (includes salt reservoir, calibration cup holder and mounting kit)
Plastic (polypropylene) flow cell kit – for general process water (includes salt reservoir, calibration cup holder and mounting kit)
Complete panel – for ultrapure water, with stainless flow cell, salt reservoir, flow meter and flow alarm on a stainless panel
✓
Recommended: 100 Ultra Series (Non-Refillable)
Sealed, maintenance-free design for low conductivity applications. Now let's configure your sensor.
Configure Your 100 Ultra Sensor
1. What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
2. What do you plan to measure?
-- Select --
pH
ORP
3. How does the cable connect to the transmitter?
-- Select --
Tagged leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
VarioPin – screw-on plug at the sensor, so you can swap the sensor without rewiring
4. Select Cable Length:
-- Select --
1 meter (3.3 ft)
3 meters (9.9 ft)
5 meters (16.4 ft)
10 meters (32.8 ft)
3. Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
I already have the cable – sensor only
4. Select Cable Length:
-- Select --
What is the pressure?
▪ <145 psi / 10 bar
Lower pressure applications
↗ >145 psi / 10 bar
High pressure applications
What is the temperature?
℃ <100Β°C / 212Β°F
Lower temperature applications
▲ >100Β°C / 212Β°F
High temperature applications
Does the process contain sticky hydrocarbons or organic solvents?
(e.g. crude oil, quench water, naphtha, ethanol, toluene or benzene)
✓ No
No sticky hydrocarbons or organic solvents
⚠ Yes
Contains hydrocarbons or organic solvents
✓ Recommended Sensors
★
500X Sensor
Based on your selections, this sensor is ideal for your industrial application.
Configure 500X β
⚙
TB5 Sensor
This is our classic heavy industrial sensor that has options like hot-tap, flow cell, high pressure, and others. This is only available as an analog sensor. If a hot-tap installation is needed, this is the sensor of choice at this time until the hardware is available for the 500X.
Configure TB5 β
⚠
Coming Soon
This selection path is under development.
β Back to pH Options
General Purpose pH/ORP Sensor Configuration
⚠
Note: The maximum pressure of this sensor is 90 psi and a minimum conductivity of 50 Β΅S/cm .
Sensor Configuration
1. What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
2. Select Measurement Type:
-- Select --
pH
ORP
3. Which glass fits the process?
Glass choices and temperature ranges are from the 100GP data sheet (DS/100GP).
-- Select --
Bullet glass (high performance) – standard applications, 32–140 °F (0–60 °C)
Flat glass (high performance) – in-line or fouling water, or where solids could break a bulb, 41–140 °F (5–60 °C)
Low-temperature glass – process always below 59 °F (15 °C), fastest response in cold water, 23–122 °F (−5 to 50 °C)
3 . Select Body Style:
Select notched ends for protection of the glass when handling.
-- Select --
Flush ends
Notched ends
4 . How does the cable connect to the transmitter?
-- Select --
Tagged leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
VarioPin – screw-on plug at the sensor, so you can swap the sensor without rewiring
5 . Select Cable Length:
-- Select --
None
1 m (3.3 ft)
3 m (9.9 ft)
5 m (16.4 ft)
10 m (32.8 ft)
4 . Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
5 . Select Integral Cable Length:
-- Select --
1 m (3.3 ft)
3 m (10 ft)
5 m (16 ft)
10 m (33 ft)
5 . Select Digital Extension Cable:
-- Select --
None
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
⚙ Transmitter Configuration
Would you like to configure a transmitter as well?
-- Select --
No
Yes
How will the transmitter get power?
-- Select --
Through its 4–20 mA signal wires only (loop powered) – 1 sensor (AWT210, 2-wire)
Its own AC or DC power wires – up to 4 sensors (2 inputs, each can take 2 digital sensors) plus relays (AWT424, 4-wire)
Would you like another sensor input module for Channel 2?
-- Select --
No
Yes β I know which module I need
Yes, but I need help determining which module to choose
Select Channel 2 Module:
-- Select --
Y0
P1
C2
C4
D1
D2
T1
U1
What type of measurement for Channel 2?
-- Select --
pH/ORP Analog β TB5, APS121, APS131, APS521, APS551
pH/ORP Digital β APS122, APS132, APS522, APS552
2-Electrode Conductivity β AC2, TB2
4-Electrode Conductivity β TB4
Turbidity/TSS β ATS430
Low Level Turbidity β ATS410
Dissolved Oxygen β ADS420
Universal Input Module β ACL410 Chlorine
The transmitter already has two 4–20 mA outputs. Do you need anything added?
-- Select --
No – the two 4–20 mA outputs are enough (most common)
Two more 4–20 mA outputs
HART – only if your plant uses it
Modbus RS-485 network – only if your plant uses it
PROFIBUS DP network – only if your plant uses it
Ethernet network – only if your plant uses it
What enclosure do you need?
-- Select --
Plastic (polycarbonate) – standard, fine for most places
Metal (aluminum) – needed for hazardous-area approvals
Power Supply:
-- Select --
90 - 265 V AC
21 - 36 V DC
Will it be in an area with flammable gas or dust (a hazardous area)?
-- Select --
No – general purpose area (cULus)
Yes – Class I Div. 2 / Zone 2 (cULus, ATEX/IECEx/UKEx) – metal enclosure only
Where will it mount?
The transmitter is rated for outdoor use. The sun shield (weathershield) mainly protects the display from sunlight (UV).
-- Select --
Flat wall – no kit needed
Pipe – pipe-mount kit
Cut-out in a panel door – panel-mount kit
Wall, in direct sun – add a sun (UV) shield
Pipe, in direct sun – pipe-mount kit + sun (UV) shield
What enclosure do you need?
-- Select --
Plastic (polycarbonate) – standard, fine for most places
Metal (aluminum) – needed for hazardous-area approvals
How will the reading get to your control system?
HART is standard. It also works as a plain 4–20 mA signal, so choose it even if the site does not use HART.
-- Select --
HART (standard) – also works as a plain 4–20 mA signal
PROFIBUS PA network – only if your plant uses it
FOUNDATION Fieldbus network – only if your plant uses it
Will it be in an area with flammable gas or dust (a hazardous area)?
Every AWT210 includes intrinsic safety (IS) approval at no extra cost, so it can move into a hazardous area later. In a non-hazardous area it is wired normally (14–42 V DC, no barrier).
-- Select --
No – general purpose area (IS approval included at no extra cost)
Yes – intrinsically safe (IS) approval, wired through an IS barrier (cFMus, ATEX/IECEx)
Yes – non-incendive and intrinsically safe approval (cFMus, ATEX/IECEx) – metal enclosure only
Where will it mount?
The transmitter is rated for outdoor use. The sun shield (weathershield) mainly protects the display from sunlight (UV).
-- Select --
Flat wall – no kit needed
Pipe – pipe-mount kit
Cut-out in a panel door – panel-mount kit
Wall, in direct sun – add a sun (UV) shield
Pipe, in direct sun – pipe-mount kit + sun (UV) shield
β Generated Transmitter Part Number
✓ Save Configuration
Installation Hardware
Do you need any installation hardware?
Available installation options displayed based on pressure and temperature limitations.
-- Select --
No hardware needed
InSert retractable assembly (Max: 311Β°F / 406 PSI)
Twist-Lock (Max: 140Β°F / 100 PSI)
T-piece flow cell (Max: 212Β°F / 87 PSI)
Flow Cell (Max: 212Β°F / 87 PSI)
Dip-mount (Max: 212Β°F / 87 PSI)
Chain mount (Pressure/temperature limits based on sensor)
Submersion
Generated Part Number
▢ Recommended Accessories
β Back to pH Options
Low Conductivity / Ultrapure Water pH Sensor Configuration
Sensor Configuration
1. What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
2. How much upkeep is OK?
-- Select --
Sealed, replace it when it wears out, lower cost (100 ULTRA)
Refill a salt (KCl) reservoir now and then – longest life and most stable in very pure water (700 ULTRA)
3. Select Measurement Type:
-- Select --
pH Measurement
ORP Measurement
4. How does the cable connect to the transmitter?
-- Select --
Tagged leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
VarioPin – screw-on plug at the sensor, so you can swap the sensor without rewiring
5. Select Cable Length:
-- Select --
1 meter
3 meters
5 meters
10 meters
4. Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
I already have the cable – sensor only
5. Select Cable Length:
-- Select --
1 meter (E01)
3 meters (E03)
5 meters (E05)
10 meters (E10)
15 meters (E15)
4. Select Connection Type:
-- Select --
V - VarioPin (cable supplied with tagged leads)
5. Select Cable Length:
-- Select --
1 meter
3 meters
5 meters
10 meters
6. Do you need a flow cell?
-- Select --
None – sensor only
Stainless steel flow cell kit – for boiler or high-purity water (includes salt reservoir, calibration cup holder and mounting kit)
Plastic (polypropylene) flow cell kit – for general process water (includes salt reservoir, calibration cup holder and mounting kit)
Complete panel – for ultrapure water, with stainless flow cell, salt reservoir, flow meter and flow alarm on a stainless panel
4. Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
I already have the cable – sensor only
5. Select Cable Length:
-- Select --
1 meter (01)
3 meters (03)
5 meters (05)
10 meters (10)
6. Do you need a flow cell?
-- Select --
None – sensor only
Stainless steel flow cell kit – for boiler or high-purity water (includes salt reservoir, calibration cup holder and mounting kit)
Plastic (polypropylene) flow cell kit – for general process water (includes salt reservoir, calibration cup holder and mounting kit)
Complete panel – for ultrapure water, with stainless flow cell, salt reservoir, flow meter and flow alarm on a stainless panel
Selected Product Configuration
Part Number:
β Back
Select Your Industry
Choose your industry to see recommended water analysis solutions
Power Generation
Boiler water, cooling water, and steam cycle monitoring
Municipal Water
Drinking water treatment and wastewater monitoring
Chemical & Petrochemical
Process water, steam generation, and wastewater
Food & Beverage
Process water and CIP monitoring
PharmaceuticalCOMING SOON
High-purity water, WFI, and purified water
Pulp & Paper
Process water, white water, and mill applications
Mining & Metals
Process water and tailings monitoring
Semiconductor / ElectronicsCOMING SOON
Ultrapure water applications
β Back to Industries
Pulp & Paper - Select Mill Area
Choose your mill area for specific water analysis solutions
Power House
Boiler water and steam cycle monitoring
Pulping Area
Process water monitoring for pulping operations
Paper Machine
White water and paper machine process control
Wastewater / Environmental
Effluent monitoring and environmental compliance
β Back to Industries
Power Generation - Water Analysis Solutions
Boiler water, cooling water, and steam cycle monitoring
Silica
Demin plants, boiler drum water & contamination monitoring
Sodium
Demin plants, boiler drum water & contamination monitoring
Dissolved Oxygen
Corrosion prevention in boiler systems - ADS550
HydrazineCOMING SOON
Oxygen scavenger monitoring
pH / ORP
Water chemistry control - Low conductivity sensors
Conductivity
Water purity monitoring - TB82/TB84/TB404
Chlorine
Cooling water biocide control
Phosphate
Boiler water treatment monitoring - AW642/AW636
Turbidity
Water clarity and filtration monitoring - ATS410/ATS430
β Back to pH Options
TB5 Part Number Generator
Configure your TB5 pH/ORP sensor by answering the questions below
☰ How to Use This Tool
Answer each question about your application requirements
Conditional options will appear based on your selections
Click Generate Part Number when all selections are made
Save the configuration to your cart for export
Description of insertion location:
Ryton Resistant:
No
Yes
Kynar Resistant:
No
Yes
Mounting Option:
-- Select --
Length of insertion into the process:
Standard submersible or threaded 1.5 in. insertion depth
0.8 in. insertion depth (choose Next Step or notched ends, not both)
2.0 in. insertion depth
2.5 in. insertion depth
3.0 in. insertion depth
3.5 in. insertion depth
4.0 in. insertion depth
4.5 in. insertion depth
5.0 in. insertion depth
Mounting Hardware:
-- Select --
Ball Valve Included:
Yes
No
Sheath Material:
-- Select --
316 Stainless
Hastelloy C
Titanium
Length of Sheath:
-- Select Material First --
Compression Hardware:
Wrench-tight compression hardware
Hand-tight hardware
Flush and Drain Housing? Not available in Hastelloy
No
Yes β Verify sheath length is sufficient. Housing is ~7.5 inches and includes ball valve.
O-Ring for Flush and Drain:
Viton
EPDM
Kalrez
RTD Selection (required for pH sensors):
None
Pt100 - Greater accuracy and stability
Balco 3K
Note: Thermocompensation is not available for ORP sensors.
Liquid Junction:
Wood β Plugging or oily water applications
PTFE β pH > 11, delignifiers, caustics, pulp & paper
Cable End Terminations:
-- Select --
Tinned
BNC
Junction Box
New Junction Box Needed?
-- Select --
Yes β New Junction Box
No β Use Existing Junction Box
Generate Part Number
β Back to Parameters
Silica Measurement System Configuration
AW641 Silica Analyzer - Configure your system
✦ Key Features
Up to 90% lower reagent consumption than competitors' analyzers
5 minute annual maintenance - labour-saving with up to 3 months unattended operation
Field upgradeable from 2β4, 2β6, or 4β6 streams
Wide range: 0-5000 Β΅g/L (ppb) SiOβ
Fast response: Results in under 10 minutes per stream
System Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
2 sample points
3 sample points
4 sample points
5 sample points
6 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. Reagent Shelf Required?
-- Select --
Yes - Include Reagent Shelf
No - No Reagent Shelf
4. What power is available?
-- Select --
Standard AC power, 110–240 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
5. Do you need a calibration certificate with the analyzer?
A paper record showing the analyzer was calibrated at the factory. Often needed for audits or quality programs.
-- Select --
No
Yes – include a calibration certificate
AW641 Silica Analyzer Configuration
Part Number:
▢ Reagent Bundle
Part Number: AW641-REB
Includes all reagents, standard, and cleaning solution for 90 days supply
β Back to Parameters
Navigator 500 Sodium Analyzer Configuration
ASO550 Sodium Analyzer - Configure your sensor
✦ Key Features
βΌ
Sampling points: Mixed beds in water treatment plant (demin), Condensate pump discharge (CPD), Main steam (MS), or polisher
Auto etching/regenerating of sodium electrode
Auto Calibration
Grab sample capable
⚠ Why Measure Sodium?
βΌ
Sodium can form Sodium Hydroxide (NaOH), which may cause caustic embrittlement . As caustic embrittlement occurs, it further accelerates the problem. Failures can occur in the boiler, and carryover in steam can cause embrittlement of the turbine.
βοΈ Standard Configuration
βΌ
β’ Process Fitting: 1/4 in (B1)
β’ Sensor Type: Reservoir fed junction
β’ Configuration: Automatic electrode configuration
Sensor Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
2. How far is the sensor section from the transmitter?
-- Select --
1.5 m (5 ft)
5 m (15 ft)
10 m (30 ft)
20 m (60 ft)
3. Do you need a factory test certificate?
A paper record showing the analyzer was tested at the factory. Often needed for audits or quality programs.
-- Select --
No
Yes – include a test certificate
4. Do you need the transmitter (the display and electronics box)?
-- Select --
Yes – needed for a new installation
No – I already have a Navigator 540 transmitter
5. How will the reading get to your control system or SCADA?
The transmitter has one slot for this. The standard choice adds the extra output card (two more 4–20 mA outputs and two alarm relays). Only choose a network if your plant already uses it; a network card takes the place of the extra output card.
-- Select --
4–20 mA signal wires, with the extra output card: 2 more 4–20 mA outputs + 2 relays (recommended)
Ethernet network (replaces the extra output card)
PROFIBUS DP network (replaces the extra output card)
Navigator 500 Sodium Analyzer Configuration
β Back to Parameters
AFM631 Fluoride Analyzer Configuration
Configure your fluoride measurement system
System Configuration
Standard Configuration:
β’ Calibration standard Level sensors
β’ SD card
β’ Calibration Certificate
β’ Reagent tray and containers
β’ Annual Maintenance Kit
1. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
4–20 mA plus Ethernet (standard)
4–20 mA plus Ethernet plus PROFIBUS DP network
AFM631 Fluoride Analyzer Configuration
Part Number:
β Back to Parameters
Turbidity / TSS Analyzer Configuration
Configure your turbidity and suspended solids measurement system
Measurement Type
1. What do you need to measure?
-- Select --
Turbidity only – how cloudy the water is (NTU)
Turbidity and suspended solids (TSS) – also how much solid material is in the water (mg/L), common in wastewater
2. How cloudy is the water at its worst?
-- Select --
Clear – drinking water, filter effluent, clean process water (0–40 NTU)
Somewhat cloudy – raw river or lake water, clarifier effluent (up to 400 NTU)
Very cloudy – wastewater, mixed liquor, sludge (above 400 NTU)
2. What will the sensor body be exposed to?
A cleaning wiper is always included.
-- Select --
Stainless steel – standard for most water and wastewater
Titanium – seawater, brine, or chemicals that corrode stainless steel
3. How far is the sensor from the transmitter?
-- Select --
3. Do you want a dry check standard?
Lets you check the sensor's accuracy in seconds without mixing liquid (formazine) standards.
-- Select --
Yes – include the check standard
No
4. How will the sensor be installed?
-- Select --
On a pole into an open tank or channel
Hanging on a chain into a basin or channel
In a flow cell that the sample water runs through
In a pipe, with an assembly that lets you pull the sensor out without shutting down
No mounting hardware needed
4a. Do you need the pole?
-- Select --
Yes – include a 2.5 m (8.2 ft) pole and a handrail bracket
No, I have my own pole – include the adapter and a handrail bracket
4a. Will you hang the chain from your own support, or do you need a swing-out arm?
-- Select --
Chain and adapter only, 3 m (9.8 ft) chain – hang it from your own support
Open-channel kit with a swing-out arm and 3 m (9.8 ft) chain – mounts at the channel edge
5. Do you need an extension cable to reach the transmitter?
-- Select --
No
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
Turbidity Analyzer Configuration
Part Number:
β Back to Parameters
Phosphate Measurement - Select Application
Choose your application type to configure the appropriate analyzer
High Purity Water
AW642 - For boiler water, steam cycle, and high-purity applications
Wastewater
AW636 - For wastewater treatment and environmental monitoring
β Back to Application Selection
Phosphate Analyzer - High Purity Water
AW642 Navigator 600 Phosphate Analyzer
System Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
2 sample points
3 sample points
4 sample points
5 sample points
6 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. What power is available?
-- Select --
Standard AC power, 110–240 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW642 Phosphate Analyzer Configuration
Part Number:
▢ Reagent Bundle
Part Number: AW642-REB
90 day supply of all reagents
β Back to Application Selection
Phosphate Analyzer - Wastewater
AW636 Aztec 600 Phosphate Analyzer
System Configuration
1. What does your process need to measure?
Orthophosphate is the phosphorus that is already dissolved and free in the water. Total phosphorus also includes phosphorus locked up in particles and organic matter. The analyzer has to break that down first (extended digestion), so each reading takes longer.
-- Select --
Orthophosphate only (faster readings)
Total phosphorus (includes extended digestion; fewer readings per hour)
2. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
4. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW636 Phosphate Analyzer Configuration
Part Number:
β Back
TB5 β 500X Series
Convert TB(X)5 pH/ORP sensors to new 500 X series
β
AP3 pH β 500X Series
Convert AP300 pH/ORP sensors to new 500 X series
β
Cross Reference Lookup
Find equivalent products from other manufacturers
β
Legacy Transmitter Converter
Convert TB82, TB84, AWT420, AWT440, and AX4 series transmitters to current models
β
β Back
Select Chlorine Application
Choose your chlorine measurement application
Drinking Water
Chlorine measurement for municipal drinking water and potable water applications
Industrial Self-Cleaning Chlorine
Self-cleaning chlorine sensors for industrial cooling water and process applications
EZTest 100 Handheld Calibrator
AWQ101 - Handheld DPD chlorine calibrator to verify ACL410, ACL411, ACL420 and ACL421 readings on site
β Back
Drinking Water Chlorine - Select Configuration
Choose sensor only or complete panel system
Sensor Only
ACL420 - Chlorine sensor for integration into existing systems
Panel System
ACL421 - Complete system including flow cell, sensor, transmitter, mounted on panel
Modular Flow Cell & Stirrer
AZA100 InFlow Multi-Cell - modular flow cell with optional Steady-Flow stirrer for the ACL420 and other ABB sensors
← Back
AZA100 InFlow Multi-Cell Configuration
The InFlow Multi-Cell holds the ACL420 ChloroStar chlorine sensor (and an optional second sensor) in the sample water. Answer the questions below and the tool picks the right options.
1. How many sensors will go in this flow cell?
-- Select --
One – chlorine sensor only
Two – chlorine sensor plus a second sensor (such as pH)
2. How much water flows through the sample line?
Tip: time how long it takes the sample line to fill a 1-gallon jug. If it takes more than 23 minutes , the flow is below 2.6 GPH (10 L/h). The stirrer works down to 0.26 GPH (1 L/h), about 1 gallon every 4 hours.
-- Select --
2.6 GPH (10 L/h) or more – no stirrer needed
Less than 2.6 GPH – add the low-flow stirrer (Steady-Flow)
Not sure – add the stirrer to be safe
3. What is the second sensor?
Look at the threads where the sensor body screws in. pH sensors such as the ABB 100E use the smaller 12 mm PG13.5 thread.
-- Select --
pH or ORP sensor with a 12 mm PG13.5 thread (such as the ABB 100E)
A second 3/4 in sensor, such as another chlorine sensor
3 . Does the water flow or pressure change during the day?
The flow control module keeps the flow steady so the reading stays stable, and it sends an alarm if the water stops so the sensor does not dry out.
-- Select --
Yes – add the flow control module
No – flow and pressure stay steady
Not sure – add the flow control module (recommended)
4 . What is the water pressure in the sample line?
Check the pressure gauge on the sample line, or ask the operator.
-- Select --
65 psi (4.5 bar) or less
More than 65 psi
Not sure
5 . What size tubing will you connect?
The flow cell uses push-in fittings. The water comes in through the smaller tube and drains out through the larger one.
-- Select --
US inch tubing – 1/4 in going in, 3/8 in going out (most common in the US)
Metric tubing – 6 mm going in, 10 mm going out
Generated Part Number:
Product: AZA100 InFlow Multi-Cell modular flow cell
Limits (DS/AZA100): sample 0–50 °C (32–122 °F), max. 4.5 bar (65 psi). Min. flow 10 L/h, or 1 L/h with the Steady-Flow module. Leave 100 mm (3.9 in) below a Steady-Flow module for its cable.
← Back
AWQ101 EZTest 100 Handheld Calibrator
Handheld DPD photometer for on-site verification of ChloroStar readings. Includes travel case, batteries, reagents (100 each of free and total), crushing rod, cell with cap, sealing ring and cleaning cloth.
Reagents:
-- Select --
Free and total chlorine tablets (0.01–6.0 ppm)
Free and total chlorine powder (0.02–3.50 ppm)
High-range free and total chlorine tablets (0.10–10.00 ppm)
Generated Part Number:
Product: EZTest 100 chlorine handheld calibrator
β Back
ACL420 Chlorine Sensor Configuration
Chlorine Type:
-- Select --
Free Chlorine
Total Chlorine
Do you need a cable to connect the sensor to the transmitter?
The sensor does not come with a cable. Choose Yes for a new installation.
-- Select --
Yes – include a cable (new installation)
No – I already have an EZLink cable (replacing a sensor)
How far is the sensor from the transmitter?
Pick the length that reaches with a little slack.
-- Select Length --
1 m (3.3 ft)
3 m (9.8 ft)
5 m (16.4 ft)
10 m (32.8 ft)
Need more than 10 m (33 ft) between the sensor and transmitter? Answer No to the cable question and add one of these longer EZLink cables instead (DS/ACL420 spares):
Generated Part Number:
Product: ACL420 Drinking Water Chlorine Sensor
β Back
ACL421 Chlorine Panel System Configuration
What power is available where the panel will hang?
-- Select --
Standard AC power, 90–265 V (a normal 120 V or 240 V circuit)
24 V DC from a control panel's DC power supply (18–36 V DC)
What is the water pressure in the line that feeds the panel?
Check the pressure gauge on the sample line, or ask the operator. Without a regulator the panel is rated to 65 psi (4.5 bar).
-- Select --
65 psi or less
More than 65 psi (up to 116 psi) – add the pressure regulator
Not sure – add the pressure regulator to be safe
More than 116 psi
Chlorine Type (Primary Channel):
-- Select --
Free Chlorine
Total Chlorine
Do you want to measure a second thing on this panel?
Adding a pH sensor lets the transmitter correct the chlorine reading when the pH changes. A digital sensor stores its own calibration and warns you before it fails; a standard (analog) sensor costs less. All sensors come with a 3 m (9.8 ft) cable.
-- Select --
No – chlorine only
Yes – pH, standard sensor (100E pH)
Yes – pH, digital sensor (100GP-D pH)
Yes – ORP, standard sensor (100E ORP)
Yes – ORP, digital sensor (100GP-D ORP)
Yes – a second free chlorine sensor
Yes – a second total chlorine sensor
How much water flows through the sample line?
Tip: time how long it takes the sample line to fill a 1-gallon jug. If it takes more than 23 minutes , the flow is below 2.6 GPH (10 L/h). The low-flow stirrer works down to 0.26 GPH (1 L/h), about 1 gallon every 4 hours.
-- Select --
2.6 GPH (10 L/h) or more – no stirrer needed
Less than 2.6 GPH – add the low-flow stirrer (Steady-Flow)
Not sure – add the stirrer to be safe
Generated Part Number:
Product: ACL421 Drinking Water Chlorine Panel System
▢ This panel system includes:
Flow cell assembly
Chlorine sensor(s)
Transmitter
All components mounted on panel
β Back
Industrial Self-Cleaning Chlorine - Select Configuration
Choose Chlorostar cell only or complete panel system
Chlorostar Cell Only
ACL410 - Chlorostar measurement cell for integration into existing systems
Panel System
ACL411 - Complete system including transmitter, cell, and reagent feed assembly mounted on panel
β Back
ACL410 Chlorostar Cell Configuration
Chlorine Measurement Type:
-- Select --
Free Chlorine
Total Chlorine
Chlorine Dioxide
What is the water pressure where the cell will connect?
Check the pressure gauge on the sample line, or ask the operator.
-- Select --
Less than 7.25 psi (0.5 bar) – very low, such as a gravity feed
7.25 to 58 psi (0.5 to 4 bar) – most sample lines
More than 58 psi (4 bar)
Not sure
What is the normal pH of the water?
Chlorine readings drift when the pH is above 7.5. If it is, a small pump adds a buffer to the sample so the reading stays accurate.
-- Select --
7.5 or lower
Above 7.5 – add the buffer pump
Not sure – add the buffer pump to be safe
What power is available for the buffer pump?
-- Select --
115 V (standard US outlet)
230 V
Do you also want to measure pH?
Adds an ABB 100E pH sensor with a 3 m (9.8 ft) cable, so you can see the pH and get an alarm if it changes suddenly.
-- Select --
Yes – add a pH sensor
No
Generated Part Number:
Product: ACL410 Chlorostar Self-Cleaning Cell
β Back
ACL411 Chlorostar Panel System Configuration
Chlorine Measurement Type:
-- Select --
Free Chlorine
Total Chlorine
Chlorine Dioxide
What power is available where the panel will hang?
-- Select --
Standard AC power, 90–265 V (a normal 120 V or 240 V circuit)
24 V DC from a control panel's DC power supply (18–36 V DC)
What is the normal pH of the water?
Chlorine readings drift when the pH is above 7.5. If it is, a small pump adds a buffer to the sample so the reading stays accurate.
-- Select --
7.5 or lower
Above 7.5 – add the buffer pump
Not sure – add the buffer pump to be safe
What power is available for the buffer pump?
-- Select --
115 V (standard US outlet)
230 V
Do you also want to measure pH?
Adds an ABB 100E pH sensor with a 3 m (9.8 ft) cable, so you can see the pH and get an alarm if it changes suddenly.
-- Select --
Yes – add a pH sensor
No
What is the water pressure in the line that feeds the panel?
Check the pressure gauge on the sample line, or ask the operator. Without a regulator the panel is rated to 60 psi (4 bar).
-- Select --
60 psi or less
More than 60 psi (up to 116 psi) – add the pressure regulator
Not sure – add the pressure regulator to be safe
Generated Part Number:
Product: ACL411 Chlorostar Panel System
▢ This panel system includes:
Transmitter
Chlorostar measurement cell
Reagent feed assembly (if required)
All components mounted on panel for easy installation
β Back
Guided Conductivity Selector
Answer a few questions and we'll recommend the best sensor for you.
β
Select by Model
Select directly from our conductivity sensor types.
β Back
AC200 Series
Sample panel and flow cell sensors
Laboratory & sample panels
TB2 Series
2-Electrode sensors
Low to moderate conductivity
TB4 Series
4-Electrode sensors
Moderate to high conductivity
TB404 Toroidal
Non-contacting sensors
Harsh, corrosive, fouling
β Back
Conductivity Sensor Selection
Answer a few simple questions to find the right conductivity sensor for your application
1. What is the expected conductivity range?
-- Select Conductivity Range --
0-200 ΞΌS/cmβ»ΒΉ
>200 ΞΌS/cmβ»ΒΉ
2. How will this be installed?
-- Select Installation Method --
Sample panel flow cell
Dip pole
Flow cell in the field
Hot-tap
Side of a tank
Threaded inline
Threaded receptacle on T
2. Is the water constantly flowing when measurement is needed?
-- Select --
Yes
No
3. Will this be in an extremely corrosive stream like sulfuric acid, caustic, brine, or other harsh chemicals?
-- Select --
Yes
No
✓ Recommended Sensor
Select the sensor that best fits your needs:
AC200 Series
Sample panel and flow cell sensors
Laboratory & sample panels
TB2 Series
2-Electrode sensors
Low to moderate conductivity
β Back
AC200 Series - Sample Panel Conductivity Sensor
Industrial conductivity cells for sample panels, flow cells, and laboratory use
1. Select based on your expected conductivity range:
-- Select --
Ultra-pure water: 0.055β20 Β΅S/cm
High purity water: 0.5β200 Β΅S/cm
General purpose: 5β2,000 Β΅S/cm
2. How will this be installed?
-- Select Option --
3. Cable connection type:
-- Select Cable Type --
Fixed cable (direct connection)
Terminal head (for field wiring)
Quick-disconnect connector
4. Cable length:
-- Select Length --
None (terminal head only)
1 meter (3.3 ft)
2 meters (6.6 ft)
5 meters (16 ft)
10 meters (33 ft)
15 meters (49 ft)
20 meters (66 ft)
Special length - consult factory
Generated Part Number(s):
β Back
TB2 Series - 2-Electrode Conductivity Sensor
Direct process mounting for low to moderate conductivity measurement
▪ Enter Your Process Conditions
Compatible models will be shown based on your temperature and pressure requirements.
1. Select sensor model:
Models shown are compatible with your process conditions
-- Select Model --
⚠ No compatible models: Your process conditions exceed the ratings of all TB2 series sensors. Consider using a different sensor type or reducing process conditions.
2. Select based on your expected conductivity range:
-- Select --
Ultra-pure water: 0.055β20 Β΅S/cm
High purity water: 0.5β200 Β΅S/cm
General purpose: 5β2,000 Β΅S/cm
3. Mounting Accessory:
-- Select Accessory --
Hot-tap length with sheath:
-- Select Hot-Tap Length --
16 in
24 in
30 in
36 in
Any compression hardware needed?
-- Select Compression Hardware --
Replacement sensor only
Hand tight compression hardware
Wrench tight compression hardware
4. Cable Length:
-- Select Length --
0 - Junction box (for field wiring)
1 - 1.5 m (5 ft)
2 - 3.0 m (10 ft)
3 - 4.6 m (15 ft)
4 - 6.1 m (20 ft)
5 - 7.6 m (25 ft)
6 - 9.1 m (30 ft)
7 - 10.7 m (35 ft)
8 - 12.2 m (40 ft)
9 - 13.7 m (45 ft)
A - 15.2 m (50 ft)
B - 22.9 m (75 ft)
C - 30.5 m (100 ft)
☀ Recommendation: For cable lengths over 30 ft (9.1 m), consider using a junction box (option 0) with an interconnecting cable. This allows easier sensor replacement in the future without needing to replace the entire cable run.
Insertion Length β What length of insertion would you need from NPT threads to the tip of the sensor?
-- Select Insertion Length --
☰ Standard Specifications (included):
Temperature Compensation: Pt1000 RTD
O-ring: Ethylene propylene (EPDM)
Electrode: 316 Stainless Steel
Insulator Tip: PEEK
Generated Part Number:
⚠
Note: Higher temperatures or amines in the process may be better suited with an AFLAS seal. Reach out to an ABB technical support specialist for more information.
⚙ Flow Cell Kits for TB264:
4TB9515-0190
Flow cell kit with Swagelok fittings
4TB9515-0223
Flow cell kit without Swagelok fittings
β Back
TB4 Series - 4-Electrode Conductivity Sensor
Wide-range measurement for moderate to high conductivity applications
▪ Enter Your Process Conditions
Compatible installation types will be shown based on your temperature and pressure requirements.
1. Select installation type:
-- Select Installation Type --
2. Select body material:
-- Select Body Material --
2. Select conductivity range:
-- Select Range --
0 - 2,000 Β΅S/cm
0 - 2,000,000 Β΅S/cm
3. Select sensor style:
-- Select Style --
4. Hot-tap mounting hardware:
-- Select Hardware --
3. Mounting style:
-- Select Mounting --
4. Cable length:
-- Select Length --
0 - Junction box (no cable)
1 - 1.5 m (5 ft)
2 - 3.0 m (10 ft)
3 - 4.5 m (15 ft)
4 - 6.0 m (20 ft)
5 - 7.6 m (25 ft)
6 - 9.1 m (30 ft)
7 - 10.6 m (35 ft)
8 - 12.1 m (40 ft)
9 - 13.7 m (45 ft)
A - 15.2 m (50 ft)
B - 22.9 m (75 ft)
C - 30.5 m (100 ft)
5. Additional insertion length:
-- Select Insertion Length --
β Back
TB404 Toroidal Conductivity Sensor
Electrode-free measurement for harsh, corrosive, or fouling applications
☰ View Datasheet
βΉοΈ Sensor Limits: Max 200Β°C (392Β°F) • Max 300 psi (2,070 kPa) • Range: 400 Β΅S/cm to 2,000 mS/cm
3. Installation type
-- Select Installation --
4. Wetted material
-- Select Material --
5. Hot tap insertion rod length
-- Select Rod Length --
6. O-ring material
-- Select O-Ring --
1 - EPDM
2 - Viton
3 - Kalrez
7. Cable length
-- Select Cable Length --
1.5 m (5 ft)
3.0 m (10 ft)
4.6 m (15 ft)
6.1 m (20 ft)
9.1 m (30 ft)
12.2 m (40 ft)
15.2 m (50 ft)
8. Identification tag
-- Select ID Tag --
None
Mylar
Stainless Steel
Generated Part Number
✓ Save Configuration
β Back
TB(X)5 to 500 X Converter
☰ How to Use This Tool
Locate your current TB(X)5 part number (e.g., TB556-3-6-P-T-10)
Select each option from the dropdowns below matching your current sensor
The equivalent 500 X part number will be generated automatically
Review the notes for any important differences or required accessories
Note: The 500 X sensors use a simplified ordering structure. Some TB(X)5 options have been consolidated or require separate accessories.
✎ Enter Your TB(X)5 Configuration
β OR β
Option 2: Use the dropdowns below:
1. Sensor Type (Mounting Style):
-- Select Sensor Type --
TB551 - Twist-lock (Ryton)
TB556 - 3/4" inline/submersible (Kynar)
TB557 - Retractable/hot-tap
TB561 - Flow cell
TB564 - High-pressure retractable
2. Measuring Electrode:
-- Select Electrode Type --
1 - Flat Glass (10-100Β°C, 0-14 pH)
2 - General-purpose Glass (0-100Β°C, 0-12 pH)
3 - High Temperature Glass (5-140Β°C, 0-14 pH)
5 - Platinum ORP
A - Gold ORP
F - Fluoride-resistant Glass (10-80Β°C, 0-12 pH)
J - Coat-resistant/High Temp Glass (5-140Β°C, 0-14 pH)
3. Integral Thermocompensation:
-- Select Thermocompensation --
0 - None
1 - 3kΞ© Balco, Tinned leads
2 - 3kΞ© Balco, Extension cable connector
3 - Pt100, Tinned leads
4 - Pt100, Extension cable connector
4. Liquid Junction:
-- Select Junction --
1 - Wood, flush
3 - PTFE, flush
4 - PTFE, recessed
5 - Wood, notched
6 - PTFE, notched
A - Wood, flush, Next Step reference
B - PTFE, flush, Next Step reference
D - Wood, notched, Next Step reference
E - PTFE, notched, Next Step reference
5. Body Style:
-- Select Body Style --
0 - Standard
7. Accessory Hardware:
-- Select Accessory --
0 - None
7. Cable Connector Type:
-- Select Cable Type --
F - BNC connector
T - Tinned/Pin leads
O - Use when JB/JS selected
8. Integral Sensor Cable Length:
-- Select Cable Length --
01 ft (0.3 m)
05 ft (1.5 m)
10 ft (3 m)
15 ft (4.6 m)
20 ft (6 m)
25 ft (7.6 m)
30 ft (9 m)
JB - With Junction Box
JS - Less Junction Box (submersible connector)
⚠ The standard length of the 500X sensor is 1.5" and cannot be modified. Please reach out to ABB for further guidance.
Retractable Insertion Hardware
Current fitting type:
-- Select Fitting Type --
Wrench-tight
Hand-tight
Material:
-- Select Material --
B1 - Stainless steel
B2 - Titanium
B3 - Hastelloy
Length:
-- Select Length --
S2 - 16 in
S3 - 20 in
S4 - 24 in
S5 - 30 in
Would you like an assisted insertion or manual insertion?
-- Select --
Manual insertion
Assisted insertion
Is a T handle needed?
-- Select --
No
Yes (J2)
Is a certification needed?
-- Select --
No
NACE (N1)
Type 2.1 material traceable (N2)
Refining your sensor selection:
7. Sensor Output Type:
-- Select Output Type --
Analog (APS551 - traditional mV output)
Digital (APS552 - EZLink)
βΉοΈ Analog Selected: Cable length will be automatically matched to your original TB5 cable length.
8. Digital Cable Configuration:
-- Select Cable Configuration --
Attached cable. This required for locations where the end of the sensor will be submerged.
Cable not connected to the sensor.
9. Integral Cable Length:
-- Select Length --
1 m (3.3 ft)
3 m (10 ft)
5 m (16 ft)
10 m (33 ft)
9. EZLink Extension Cable:
-- Select Extension Cable --
None (no extension cable)
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
Note: Integral cable length = 00 (none).
⚠ Junction boxes are only available with the analog version. The digital version will not have a junction box.
Replacement Part Numbers
500X sensor:
Insertion hardware:
⚠ The hardware for replacement requires a 1.5" NPT full port ball valve. Verify the current ball valve size.
The length and material most closely match what is currently in the field. Modifications to material and length can be selected.
Save Both to Configurations
⚠ Digital sensors require the EZLink module for the AWT420, AWT424, or AWT210 transmitters.
⚙ Recommended Accessories
β Back
Dissolved Oxygen Sensor Selection
Answer a few simple questions to find the right DO sensor for your application
1. What is your application?
This decides which sensor fits.
-- Select Application --
Wastewater – aeration basin, lagoon, open tank (measures in ppm)
Power plant – boiler feedwater, condensate (measures very low oxygen, in ppb)
Semiconductor / ultrapure water – the lowest trace levels
Recommended Sensor
Continue to Configuration β
β Back
ADS420 Optical Dissolved Oxygen Sensor
Optical DO sensor for wastewater and environmental applications (0-50 mg/L)
1. Will the sensor be submerged in water (tank, basin, lagoon)?
Submerged installations require an integral cable
-- Select --
Yes - Sensor will be submerged in water
No - Sensor will be in a flow cell or pipe
2. How will the sensor be installed?
Check all that apply. Choices that cannot be ordered together are blocked automatically.
3. Does your site have compressed air available for sensor cleaning?
EZClean uses air bursts to keep the sensor clean automatically
-- Select --
Yes - We have compressed air on site
No - We need a compressor system
4. What power is available for the air compressor?
-- Select Voltage --
115 V (standard US outlet)
230 V
4. Do you need an extension cable to reach the transmitter?
Extension cables can be added to reach the transmitter
-- Select --
No
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
β Back
Navigator 500 Dissolved Oxygen Analyzer (ADS550)
High-purity water DO analyzer for power plant applications (0-20,000 ppb)
Standard Configuration Included:
Sensor: S1 - Standard sensor included
Process Connection: B1 - 1/4 inch fitting
A1 - Auto calibration valve
B1 - Sample flow control valve
S1 - Sample flow measurement
1. How far is the sensor section from the transmitter?
-- Select --
No cable needed (I already have one)
1.5 m (5 ft)
5 m (15 ft)
10 m (30 ft)
20 m (60 ft)
2. Do you need the transmitter (the display and electronics box)?
-- Select --
Yes – needed for a new installation
No – I already have a Navigator 540 transmitter
3. How will the reading get to your control system or SCADA?
The transmitter has one slot for this. The standard choice adds the extra output card (two more 4–20 mA outputs and two alarm relays). Only choose a network if your plant already uses it; a network card takes the place of the extra output card.
-- Select --
4–20 mA signal wires, with the extra output card: 2 more 4–20 mA outputs + 2 relays (recommended)
Ethernet network (replaces the extra output card)
PROFIBUS DP network (replaces the extra output card)
Navigator 500 DO Analyzer Configuration
β Back
AeroStar Ultra Series - Low-Level Dissolved Oxygen
Optical sensors for ultra-low DO measurement in semiconductor and power applications
1. How low are the oxygen levels you need to measure?
-- Select --
Down to 4 ppb – power plants, boiler feedwater (AeroStar Ultra, 4 ppb to 25 ppm)
Down to 0.8 ppb – semiconductor, highest purity (AeroStar Ultra Trace, 0.8 to 2,000 ppb)
2. Do you need the cable from the sensor to the transmitter?
-- Select --
Yes – include the 3 m (9.8 ft) cable (needed for a new install)
No – I already have one
3. Do you need an extension cable to reach the transmitter?
-- Select --
No
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
4. Do you need a flow cell to hold the sensor in the sample line?
-- Select --
Yes – include a stainless steel flow cell with mounting kit
No
AeroStar Ultra Configuration
β Back to Parameters
Aluminum Analyzer Configuration
AW631 Aztec 600 Aluminum Analyzer
☰ How to Use This Tool
Complete the questions below to generate your part number.
System Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW631 Aluminum Analyzer Configuration
Part Number:
β Back to Parameters
Ammonia / Ammonium Analyzer Configuration
Configure your ammonia measurement system
Measurement Range Selection
1. What are the highest ammonia levels you expect?
-- Select --
Up to 3 ppm – drinking water, chloramine control, clean effluent (Aztec AW632, color method)
Above 3 ppm, up to 1,000 ppm – raw wastewater, digesters, industrial (AAM631, ion-selective electrode)
Not sure – ask for a recent lab result. Under 3 ppm is typical for treated water.
AW632 Aztec 600 Ammonia Analyzer (Low Range)
Colorimetric analyzer for trace ammonia measurement
2. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
3. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
4. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AAM631 Ammonia ISE Analyzer (High Range)
Ion-selective electrode analyzer for ammonia measurement up to 1000 ppm
2. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
3. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
4–20 mA plus Ethernet (standard)
4–20 mA plus Ethernet plus PROFIBUS DP network
Ammonia Analyzer Configuration
Part Number:
β Back to Parameters
Iron Analyzer Configuration
AW633 Aztec 600 Iron Analyzer
System Configuration
1. What does your process need to measure?
Dissolved iron is the iron already free in the water. Total iron also includes iron locked up in particles. The analyzer has to break those down first (digestion), so readings are slower and only 1 sample point can be measured.
-- Select --
Dissolved iron only (faster readings)
Total iron (includes digestion; slower readings, 1 sample point only)
2. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW633 Iron Analyzer Configuration
Part Number:
β Back to Parameters
Manganese Measurement - Select Range
Choose the measurement range that best fits your application
High Range
AW635 - 0.02 to 10 ppm Mn For higher concentration applications
Low Range
AW634 - 0 to 0.1 ppm Mn For trace level detection
β Back to Range Selection
Manganese Analyzer - High Range
AW635 Aztec 600 Manganese Analyzer (0.02 - 10 ppm)
System Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW635 Manganese Analyzer Configuration
β Back to Range Selection
Manganese Analyzer - Low Range
AW634 Aztec 600 Manganese Analyzer (0 - 0.1 ppm)
System Configuration
1. How many sample points will this one analyzer check?
One analyzer can test water from more than one pipe. It checks them one at a time, in rotation, so each point gets a reading every few minutes.
-- Select --
1 sample point
3 sample points
2. How will the reading get to your control system or SCADA?
Every analyzer has a 4–20 mA output. Only choose a network if your plant already uses it. Ask the controls or I&C person if unsure.
-- Select --
Standard 4–20 mA signal wire (most common)
PROFIBUS DP network (also keeps the 4–20 mA output)
3. What power is available?
-- Select --
Standard AC power, 90–264 V (a normal 120 V or 240 V circuit)
18–36 V DC from a control panel
AW634 Manganese Analyzer Configuration
β Back to Parameters
BOD / COD Measurement
Select your product type
Portable Field Meter
UviTec AUV101 - Simple and affordable BOD/COD testing
Sensor
BOD/COD sensor application questionnaire
β Back to BOD/COD Selection
UviTec BOD/COD Field Meter
AUV101 - Portable BOD/COD analyzer
System Configuration
1. Select Your Industry:
-- Select --
Municipal
Dairy
Brewery
Pulp & Paper
Food & Beverage
2. Select Your Range:
-- Select --
UviTec BOD/COD Field Meter Configuration
Part Number:
β Back to Parameters
TOC / DOC Measurement
Select your product type
Portable Field Meter
UviTec AUV102 - Simple and affordable TOC/DOC testing
β Back to TOC/DOC Selection
UviTec TOC/DOC Field Meter
AUV102 - Portable TOC/DOC analyzer
System Configuration
1. Select Your Industry:
-- Select --
Municipal
Dairy
Brewery
Pulp & Paper
Food & Beverage
2. Select Your Range:
-- Select --
UviTec TOC/DOC Field Meter Configuration
Part Number:
β Back to BOD/COD Selection
BOD/COD Sensor Application Questionnaire
Please provide the following information to help us recommend the best solution
β Back to pH Options
500X pH/ORP Sensor Builder
Answer the questions below to configure your ideal 500X sensor
Your 500X Part Number
APS5XX
ORP Configuration
Does the process contain any of the following: Zinc, Cadmium, Nickel, or Cyanide?
Zinc, Cadmium, Nickel, or Cyanide require a gold ORP electrode instead of platinum.
-- Select --
Yes
No
pH Glass Selection
Is this in an area with solids or other abrasive materials that could damage the glass?
-- Select --
Yes
No
Does the process contain hydrofluoric acid (HF) or fluoride? HF damages normal glass.
-- Select --
Yes
No
Junction Type
What's in the water?
-- Select --
Oil, grease, or things that clog – wood junction
Strong chemicals, pulp and paper, pH above 11.5, or most other water – PTFE junction
Body Style
What would you like the ends to be?
Select notched ends for protection of the glass when handling.
-- Select --
Notched
Flush
Sensor Type
What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog (APS551) – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) (APS552) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
Analog Limitations:
β’ Max 435 PSI at less than 212Β°F (100Β°C)
β’ Max 406 PSI up to 311Β°F (155Β°C)
Digital Limitations:
β’ Max 435 PSI at 212Β°F (100Β°C)
Analog Configuration (APS551)
How does the cable connect to the transmitter?
-- Select --
Tagged leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
VarioPin – screw-on plug at the sensor, so you can swap the sensor without rewiring
What cable length would you like?
-- Select --
Would you like an extension cable?
-- Select --
None
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
Is a junction box needed?
-- Select --
No
Yes
Digital Configuration (APS552)
Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
What length of cable?
-- Select --
1 m (3.3 ft)
3 m (9.9 ft)
5 m (16.4 ft)
10 m (32.8 ft)
Would you like an extension cable?
-- Select --
None
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
Installation Hardware
Do you need any installation hardware?
Available installation options displayed based on pressure and temperature limitations.
-- Select --
No hardware needed
InSert retractable assembly (Max: 311Β°F / 406 PSI)
Twist-Lock (Max: 140Β°F / 100 PSI)
T-piece flow cell (Max: 212Β°F / 87 PSI)
Flow Cell (Max: 212Β°F / 87 PSI)
Dip-mount (Max: 212Β°F / 87 PSI)
Chain mount (Pressure/temperature limits based on sensor)
Submersion
β Your Configured 500X Sensor
β Back to pH Options
500 PRO pH/ORP Sensor Builder
Answer the questions below to configure your ideal 500 PRO sensor
Your 500 PRO Part Number
APS52X
500 PRO Specifications
Maximum Pressure: 145 PSI (10 bar) for all versions
ORP Configuration
ORP Platinum Electrode: 0 to 100 Β°C (32 to 212 Β°F)
The 500 PRO ORP sensor uses a platinum electrode (R2).
pH Glass Selection
Is this in an area with solids or other abrasive materials that could damage the glass?
-- Select --
Yes - Flat glass recommended
No
Does the process contain hydrofluoric acid (HF) or fluoride? HF damages normal glass.
-- Select --
Yes
No
Is the process temperature consistently below 50 Β°C (122 Β°F)?
-- Select --
Yes - Low temperature glass recommended for faster response
No
Is the process temperature above 100 Β°C (212 Β°F)?
-- Select --
Yes - High temperature glass needed
No - High performance glass recommended
Body Style
What would you like the ends to be?
Select notched ends for protection of the glass when handling.
-- Select --
Notched
Flush
Sensor Type
What will the sensor connect to?iAnalog – the sensor sends its signal straight to the transmitter. Works with almost any pH transmitter, including other brands. Calibration is stored in the transmitter, so the sensor is calibrated where it is installed.Digital (EZLink) – the sensor has electronics inside that store its own calibration and health data. It can be calibrated in a shop or lab and swapped in the field, and it warns you before it fails. It only connects to an ABB AWT210, AWT420 or AWT424 with a digital (EZLink) module.
-- Select --
Analog (APS521) – works with any pH transmitter, or when replacing an existing sensor
Digital (EZLink) (APS522) – connects to an ABB AWT210, AWT420 or AWT424 with a digital module; stores its own calibration and warns before it fails
Analog Configuration (APS521)
How does the cable connect to the transmitter?
-- Select --
Tagged leads – bare wires that screw into terminals (most common)
BNC – round twist-on plug, like on lab meters and some panel instruments
VarioPin – screw-on plug at the sensor, so you can swap the sensor without rewiring
What cable length would you like?
-- Select --
Would you like an extension cable?
-- Select --
None
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
Is a junction box needed?
-- Select --
No
Yes
Digital Configuration (APS522)
Will the end of the sensor sit underwater, such as hanging in a tank or basin?
-- Select --
Yes – sealed, attached cable
No – removable cable, so the sensor can be swapped without rewiring
What length of cable?
-- Select --
1 m (3.3 ft)
3 m (9.9 ft)
5 m (16.4 ft)
10 m (32.8 ft)
Would you like an extension cable?
-- Select --
None
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
Installation Hardware
Do you need any installation hardware?
Available installation options displayed based on pressure and temperature limitations.
-- Select --
No hardware needed
InSert retractable assembly (Max: 311Β°F / 406 PSI)
Twist-Lock (Max: 140Β°F / 100 PSI)
T-piece flow cell (Max: 212Β°F / 87 PSI)
Flow Cell (Max: 212Β°F / 87 PSI)
Dip-mount (Max: 212Β°F / 87 PSI)
Chain mount (Pressure/temperature limits based on sensor)
Submersion
β Your Configured 500 PRO Sensor
β Back to Industries
Municipal Water - Water Analysis Solutions
Drinking water treatment and wastewater monitoring
Chlorine
Disinfection monitoring for safe drinking water
pH / ORP
Water chemistry and disinfection control
Conductivity
Water quality and TDS monitoring
Turbidity
Water clarity and filtration efficiency
Dissolved Oxygen
Aeration and biological treatment monitoring
Ammonia
Nitrogen removal and chloramine monitoring
Phosphate
Phosphorus removal to prevent algae growth downstream
Aluminum
Coagulation optimization and compliance
Iron
Water quality and aesthetic compliance
Manganese
Water quality and aesthetic compliance
BOD / COD
Organic matter and treatment efficiency
Fluoride
Fluoridation control for dental health
β Back to Industries
Food & Beverage - Water Analysis Solutions
Process water and CIP monitoring
pH / ORP
Process control and CIP monitoring
Conductivity
CIP rinse verification and water quality
Dissolved Oxygen
Fermentation and packaging applications
BOD / COD
Wastewater monitoring and treatment efficiency
β Back to Mill Areas
Pulp & Paper - Power House
Boiler water and steam cycle monitoring
Silica
Boiler water monitoring - AW641 Navigator 600
Sodium
Demin plants, boiler drum water & contamination monitoring
Dissolved Oxygen
Corrosion prevention in boiler systems - ADS550
pH / ORP
Water chemistry control
Conductivity
Water purity monitoring
Chlorine
Cooling water biocide control
Phosphate
Boiler water treatment monitoring
Turbidity
Water clarity and filtration monitoring
β Back to Mill Areas
Pulp & Paper - Pulping Area
Process water monitoring for pulping operations
Conductivity
Process liquor monitoring
pH / ORP
Pulping process control
β Back to Mill Areas
Pulp & Paper - Paper Machine
White water and paper machine process control
pH / ORP
White water chemistry control
Conductivity
White water quality monitoring
β Back to Mill Areas
Pulp & Paper - Wastewater / Environmental
Effluent monitoring and environmental compliance
pH / ORP
Effluent pH control
Conductivity
Effluent quality monitoring
BOD / COD
Organic load and treatment efficiency
Dissolved Oxygen
Aeration and biological treatment
Phosphate
Nutrient discharge monitoring
Ammonia
Nitrogen discharge monitoring
β Back
AP300 to 500 X Converter
☰ How to Use This Tool
Locate your current AP300 part number (e.g., AP302.1.1.0.1.0.00.1)
Select each option from the dropdowns below matching your current sensor
The equivalent 500 X part number will be generated automatically
Review the notes for any important differences or required accessories
Note: The 500 X sensors use a simplified ordering structure. All AP300 sensors use PTFE junctions which map to the standard 500X configuration.
✎ Enter Your AP300 Configuration
β OR β
Option 2: Use the dropdowns below:
Current AP300 Part Number:
AP30_ ._ ._ .0 ._ ._ .__ ._
1. Body Style:
-- Select Body Style --
1 - AP301 Twist-lock insertion (TB551 style)
2 - AP302 3/4" threaded, flush (TB556 style)
3 - AP303 3/4" threaded, notched (TB556 style)
4 - AP304 Ball valve hot-tap, flush (TB557 style)
5 - AP305 Ball valve hot-tap, notched (TB557 style)
2. Measuring Electrode:
-- Select Electrode --
1 - Flat pH glass (self-cleaning)
2 - Standard pH glass (bulb, general purpose)
3 - Low resistance glass
5 - Platinum ORP
3. Integral Temperature Sensor:
-- Select Temperature Sensor --
4. Junction:
-- Select Junction --
0 - Standard PTFE Junction
5. Junction Box or Integral Cable Length:
-- Select Cable Option --
0 - Short cable, no junction box
1 - 3 m (10 ft)
2 - 6 m (20 ft)
3 - 9 m (30 ft)
8 - Integral junction box
6. Sensor Connectors:
-- Select Connector --
0 - Tagged pin leads
1 - BNC connectors
7. Accessory Hardware:
-- Select Hardware --
8. Manual:
-- Select Manual --
0 - None
1 - English
2 - French
3 - German
4 - Spanish
Refining your sensor selection:
8. What type of installation will this be?
-- Select Installation Type --
Industrial
Municipal
9. Sensor Output Type:
-- Select Output Type --
Analog (traditional mV output)
Digital (EZLink)
10. Analog Cable Length:
-- Select Cable Length --
01 meters (3 ft)
03 meters (10 ft)
05 meters (16 ft)
10 meters (33 ft)
10. Digital Cable Configuration:
-- Select Cable Configuration --
Attached (The cable is connected to the sensor and required for water submerged applications)
Detached (The cable is not connected to the sensor)
11. Integral Cable Length:
-- Select Length --
1 m (3.3 ft)
3 m (10 ft)
5 m (16 ft)
10 m (33 ft)
10. EZLink Extension Cable:
-- Select Extension Cable --
None (no extension cable)
1 m (3.3 ft)
5 m (16.4 ft)
10 m (32.8 ft)
15 m (49.2 ft)
25 m (82 ft)
50 m (164 ft)
Note: Integral cable length = 00 (none).
⚙ Recommended Accessories
β Back to Converters
TB82 β AWT210
2-wire loop-powered conductivity or pH transmitter
β
TB84 β AWT424
Line-powered conductivity or pH transmitter
β
AX4 β AWT424
Single-channel analyzer
β
AWT440 β AWT424
Multi-input transmitter
β
AWT420 β AWT424
Single-input transmitter
β
β Back
TB82 to AWT210 Converter
Enter your TB82 configuration to generate the equivalent AWT210 part number
☰ How to Use This Tool
Locate your current legacy transmitter part number (e.g., TB82PH10010 )
Read your part number and enter each value as you go down the list, choosing the part number displayed on your legacy transmitter.
Do not skip ahead as the prompts are in the same order as the legacy part number transmitter is written.
The equivalent part number will be generated automatically.
Your TB82 Part Number
TB82
TB82 Configuration
1. Input Type:
TB82PH 1001020
-- Select --
TE
EC
TC
PH
2. Option:
TB82PH1 001020
-- Select --
1
2
3. Communication:
TB82PH10 01020
-- Select --
0
1
2
3
4. Lightning Suppressor:
TB82PH100 1020
-- Select --
1
5. Housing:
TB82PH1001 020
-- Select --
0
6. Mounting Options:
TB82PH10010 20
-- Select --
0
1
2
3
4
7. Agency Approvals:
TB82PH100102 0
-- Select --
0
1
2
3
8. Additional Option (Optional):
TB82PH1001020
-- Select --
0
1
2
▢ Add to Cart
β Back
TB84 to AWT424 Converter
Enter your TB84 configuration to generate the equivalent AWT424 part number
☰ How to Use This Tool
Locate your current legacy transmitter part number (e.g., TB84EC100010 )
Read your part number and enter each value as you go down the list, choosing the part number displayed on your legacy transmitter.
Do not skip ahead as the prompts are in the same order as the legacy part number transmitter is written.
The equivalent part number will be generated automatically.
Your TB84 Part Number
TB84
TB84 Configuration
1. Input Type:
TB84EC 1000100
-- Select --
EC
TE
TC
PH
2. Option:
TB84EC1 000100
-- Select --
1
2
3. Option:
TB84EC10 00100
-- Select --
0
4. Option:
TB84EC100 0100
-- Select --
0
5. Option:
TB84EC1000 100
-- Select --
0
6. Mounting Options:
TB84EC10001 00
-- Select --
0
1
2
3
4
7. Agency Approvals:
TB84EC100010 0
-- Select --
0
1
2
8. Option:
TB84EC1000100
-- Select --
0
1
2
AWT424 Channel 2 Option
The upgraded AWT424 has the capability to support an additional sensor input. Would you like to add one?
Channel 2 Input:
No, keep this the same
An additional 2-electrode conductivity module
An additional 4-electrode conductivity module
A digital sensor module
A dual digital sensor module
An additional pH module
A module to measure low level turbidity
A module to measure chlorine with the ACL410
⚠ The AWT424 does not support toroidal sensors at this time. Please reach out to your ABB Technical Sales Specialist for assistance.
β Back
AX4 to AWT424 Converter
Enter your AX4 configuration to generate the equivalent AWT424 part number
☰ How to Use This Tool
Locate your current legacy transmitter part number (e.g., AX461210 )
Read your part number and enter each value as you go down the list, choosing the part number displayed on your legacy transmitter.
Do not skip ahead as the prompts are in the same order as the legacy part number transmitter is written.
The equivalent part number will be generated automatically.
AX4 Configuration
1. Channel 1 Input:
AX46 1210
-- Select --
1
3
5
6
8
2. Channel 2 Input:
AX461 210
-- Select --
0
1
3
5
6
8
3. Mounting:
AX4612 10
-- Select --
1
2
5
6
7
⚠ Panel Mount Note: The dimensions of the AX4 panel mount transmitter was 3.77" X 3.77". The new dimensions required for the AWT424 panel mount replacement is 5.67" X 5.67". Onsite modifications will need to be made to fit. Refer to data sheet or instructions for more information on installation.
4. Communication:
AX46121 0
-- Select --
0
1
2
3
5. Power:
AX461210
-- Select --
0
1
⚠ The dissolved oxygen system that was supported on the AX48 is no longer available. In order to read dissolved oxygen, you will also need to have the ADS420 dissolved oxygen digital sensor or reach out to your ABB technical sales specialist for guidance.
✓ Save Configuration
β Back
AWT440 to AWT424 Converter
Enter your AWT440 configuration to generate the equivalent AWT424 part number
☰ How to Use This Tool
Locate your current legacy transmitter part number (e.g., AWT440.A.1.A.1.2.D2.Y0.Y0.Y0-A1 )
Read your part number and enter each value as you go down the list, choosing the part number displayed on your legacy transmitter.
Do not skip ahead as the prompts are in the same order as the legacy part number transmitter is written.
The equivalent part number will be generated automatically.
Your AWT440 Part Number
AWT440
AWT440 Configuration
1. Option:
AWT440.A .1.A.1.2.D2.Y0.Y0.Y0-A1
-- Select --
A
2. Option:
AWT440.A.1 .A.1.2.D2.Y0.Y0.Y0-A1
-- Select --
1
3. Option:
AWT440.A.1.A .1.2.D2.Y0.Y0.Y0-A1
-- Select --
A
4. Power:
AWT440.A.1.A.1 .2.D2.Y0.Y0.Y0-A1
-- Select --
1
2
5. Option:
AWT440.A.1.A.1.2 .D2.Y0.Y0.Y0-A1
-- Select --
D2
6. Channel 2:
AWT440.A.1.A.1.2.D2 .Y0.Y0.Y0-A1
-- Select --
D2
Y0
7. Output:
AWT440.A.1.A.1.2.D2.Y0 .Y0.Y0-A1
-- Select --
Y0
Y2
8. Communications:
AWT440.A.1.A.1.2.D2.Y0.Y0 .Y0-A1
-- Select --
Y0
E1
D1
M1
9. Option:
AWT440.A.1.A.1.2.D2.Y0.Y0.Y0 -A1
-- Select --
Y0
D1
D2
D8
10. Mounting:
AWT440.A.1.A.1.2.D2.Y0.Y0.Y0-A1
-- Select --
A1
A2
A3
A4
▢ Add to Cart
β Back
AWT420 to AWT424 Converter
Enter your AWT420 configuration to generate the equivalent AWT424 part number
☰ How to Use This Tool
Locate your current legacy transmitter part number (e.g., AWT420/B.2.A1.D1.Y0.E1.E5-A1.U3.D1.T1.M5 )
Read your part number and enter each value as you go down the list, choosing the part number displayed on your legacy transmitter.
Do not skip ahead as the prompts are in the same order as the legacy part number transmitter is written.
The equivalent part number will be generated automatically.
Your AWT420 Part Number
AWT420
AWT420 Configuration
1. Model Option:
AWT420/B .2.A1.D1.Y0.E1.E5-A1.U3.D1.T1.M5
-- Select --
A
B
2. Enclosure Type:
AWT420/B.2 .A1.D1.Y0.E1.E5-A1.U3.D1.T1.M5
-- Select Enclosure --
1
2
3. Power Supply:
AWT420/B.2.A1 .D1.Y0.E1.E5-A1.U3.D1.T1.M5
-- Select Power Supply --
A1
D1
4. Sensor Input Module β Channel 1:
AWT420/B.2.A1.D1 .Y0.E1.E5-A1.U3.D1.T1.M5
-- Select --
Y0
P1
C2
C4
D1
T1
U1
5. Sensor Input Module β Channel 2:
AWT420/B.2.A1.D1.Y0 .E1.E5-A1.U3.D1.T1.M5
-- Select --
Y0
P1
C2
C4
D1
T1
U1
6. Communications Module:
AWT420/B.2.A1.D1.Y0.E1 .E5-A1.U3.D1.T1.M5
-- Select --
Y0
H1
M1
D1
E1
A1
7. Agency Approvals:
AWT420/B.2.A1.D1.Y0.E1.E5 -A1.U3.D1.T1.M5
-- Select --
E5
E3
8. Mounting Accessories:
AWT420/B.2.A1.D1.Y0.E1.E5-A1 .U3.D1.T1.M5
-- Select --
A1
A2
A3
A4
9. Cable Entry:
AWT420/B.2.A1.D1.Y0.E1.E5-A1.U3 .D1.T1.M5
-- Select --
U1
U3
10. SD Card:
AWT420/B.2.A1.D1.Y0.E1.E5-A1.U3.D1 .T1.M5
-- Select --
D1
11. Temperature:
AWT420/B.2.A1.D1.Y0.E1.E5-A1.U3.D1.T1 .M5
-- Select --
T1
12. Documentation:
AWT420/B.2.A1.D1.Y0.E1.E5-A1.U3.D1.T1.M5
-- Select --
M5
▢ Add to Cart
β Back to Industries
Chemical & Petrochemical - Water Analysis Solutions
Select your application area
Steam Generation
Boiler feedwater, condensate, and steam cycle monitoring
Process
Process water quality monitoring
Wastewater
Effluent treatment and discharge monitoring
β Back to Chemical & Petrochemical
Steam Generation - Water Analysis Solutions
Boiler feedwater, condensate, and steam cycle monitoring
Silica
Boiler feedwater and steam purity
Sodium
Demineralizer breakthrough and steam purity
Dissolved Oxygen
Deaerator performance and corrosion control
pH / ORP
Boiler water chemistry control
Conductivity
Condensate purity and blowdown control
Chlorine
Cooling water treatment
Phosphate
Boiler water treatment monitoring
Turbidity
Makeup water clarifier performance
HydrazineCOMING SOON
Oxygen scavenger monitoring
β Back to Chemical & Petrochemical
Process - Water Analysis Solutions
Process water quality monitoring
pH / ORP
Process control and neutralization
Conductivity
Process water quality and purity
β Back to Chemical & Petrochemical
Wastewater - Water Analysis Solutions
Effluent treatment and discharge monitoring
pH / ORP
Neutralization and treatment control
Conductivity
Effluent quality monitoring
Dissolved Oxygen
Aeration basin control
BOD / COD
Organic load monitoring
Turbidity
Effluent clarity and TSS correlation